Features:
- Ultra low attenuation
 - Copper Shield
 - Low VSWR
 - Wide Frequency Range
 - Excellent Power Rating
 - UV Resistant
 
| 
 Materials and Dimensions  | 
|
| 
 Inner conductor-helicat corrugated copper  | 
 4.8 mm / 0.189 in  | 
| 
 Dialectric-foam PE  | 
 12.1 mm / 0.476 in  | 
| 
 Outer conductor- corrugated copper tube  | 
 13.8 mm / 0.543 in  | 
| 
 Diameter over outer jacket- polythylene black  | 
 15.9 mm / 0.626 in  | 
| 
 Mechanical Specifications  | 
|
| 
 Cable Weight  | 
 0.17 kg/m | 0.114 lbs/ft  | 
| 
 Tensile Strength  | 
 1150 N | 258 lbs  | 
| 
 Min. Bending Radius (single)  | 
 71 mm | 2.79 inches  | 
| 
 Min. Bending Radius (repeated)  | 
 125 mm | 4.96 inches  | 
| 
 Number of bends, minimum (typical)  | 
 15 (50)  | 
| 
 Recommended Hanger Spacing  | 
 0.8 m | 2.62 ft  | 
| 
 Environmental Specifications  | 
|
| 
 Installation Temperature  | 
 -25°C to +60°C  | 
| 
 Operating Temperature  | 
 -40°C to +85°C  | 
| 
 Storage Temperature  | 
 -70°C to +85°C  | 
| 
 2002/95/EC (RoHS)  | 
 compliant  | 
| 
 Return Loss  | 
|
| 
 1 to 1000 MHz  | 
 Return Loss: ≤-26 dB | VSWR: ≤ 1.105:1  | 
| 
 1000 to 1900 MHz  | 
 Return Loss: ≤-24 dB | VSWR: ≤ 1.140:1  | 
| 
 1900 to 2200 MHz  | 
 Return Loss: ≤-24 dB | VSWR: ≤ 1.140:1  | 
| 
 2200 to 2500 MHz  | 
 Return Loss: ≤-24 dB | VSWR: ≤ 1.140:1  | 
| 
 2500 to 3000 MHz  | 
 Return Loss: ≤-24 dB | VSWR: ≤ 1.140:1  | 
| 
 Electrical Specifications  | 
|
| 
 Impedance  | 
 50 ± 1 Ω  | 
| 
 Relative Velocity of Propogation  | 
 88%  | 
| 
 Capacitance (1kHz)  | 
 76 pF/m  | 
| 
 Inductance  | 
 0.190 µH/m  | 
| 
 Maximum Operating Frequency  | 
 8.8 GHz  | 
| 
 Cut-off Frequency  | 
 10.0 GHz  | 
| 
 Peak Power Rating  | 
 40 kW  | 
| 
 Insulation Resistance  | 
 ≥ 10 GΩ x km  | 
| 
 DC Breakdown Voltage  | 
 6000 V  | 
| 
 Jacket Spark Test Voltage  | 
 8000 Vrms  | 
| 
 Inner Conductor DC-resistance  | 
 ≤ 1.5 Ω /km  | 
| 
 Outer Conductor DC-resistance  | 
 ≤ 2.3 Ω /km  | 
| 
 Attenuation  | 
||
| 
 Frequenxy (MHz)  | 
 Attenuation (dB/100m)  | 
 Average Power (kW)  | 
| 1 | 0.20 | 35.89 | 
| 
 100  | 
 2.15  | 
 3.94  | 
| 
 200  | 
 3.08  | 
 2.75  | 
| 
 300  | 
 3.81  | 
 1.99  | 
| 
 400  | 
 4.46  | 
 1.80  | 
| 
 450  | 
 4.70  | 
 1.80  | 
| 
 800  | 
 6.35  | 
 1.33  | 
| 
 900  | 
 6.75  | 
 1.25  | 
| 
 1000  | 
 7.20  | 
 1.18  | 
| 
 1800  | 
 9.90  | 
 0.86  | 
| 
 2000  | 
 10.50  | 
 0.81  | 
| 
 2200  | 
 11.10  | 
 0.77  | 
| 
 2500  | 
 11.95  | 
 0.73  | 
| 
 2700  | 
 12.47  | 
 0.69  | 
| 
 3000  | 
 13.20  | 
 0.65  | 
| 
 Standard Conditions  | 
|
| 
 Attenuation, Ambient Temperature  | 
 20̊ C  | 
| 
 Average Power, Ambient Temperature  | 
 40̊ C  | 
| 
 Average Power, Inner Conductor Temperature  | 
 100̊ C  | 
| 
 Ordering Information  | 
||
| 
 Part Number  | 
 Description  | 
 UOM  | 
| 
 AAT-12-FC  | 
 1/2” 50 ohm Coaxial Cable  | 
 Per Ft.  | 
Disclaimer: Specifications are subject to change without notice. Information may be changed or updated without notice. American Amplifier TechnologiesTM may also make improvements and/or changes in the products and/or pricing described at any time without notice.
            
              