Features:
- Ultra low attenuation
- Copper Shield
- Low VSWR
- Wide Frequency Range
- Excellent Power Rating
- UV Resistant
| Materials and Dimensions | |
| Inner conductor-helicat corrugated copper | 4.8 mm / 0.189 in | 
| Dialectric-foam PE | 12.1 mm / 0.476 in | 
| Outer conductor- corrugated copper tube | 13.8 mm / 0.543 in | 
| Diameter over outer jacket- polythylene black | 15.9 mm / 0.626 in | 
| Mechanical Specifications | |
| Cable Weight | 0.17 kg/m | 0.114 lbs/ft | 
| Tensile Strength | 1150 N | 258 lbs | 
| Min. Bending Radius (single) | 71 mm | 2.79 inches | 
| Min. Bending Radius (repeated) | 125 mm | 4.96 inches | 
| Number of bends, minimum (typical) | 15 (50) | 
| Recommended Hanger Spacing | 0.8 m | 2.62 ft | 
| Environmental Specifications | |
| Installation Temperature | -25°C to +60°C | 
| Operating Temperature | -40°C to +85°C | 
| Storage Temperature | -70°C to +85°C | 
| 2002/95/EC (RoHS) | compliant | 
| Return Loss | |
| 1 to 1000 MHz | Return Loss: ≤-26 dB | VSWR: ≤ 1.105:1 | 
| 1000 to 1900 MHz | Return Loss: ≤-24 dB | VSWR: ≤ 1.140:1 | 
| 1900 to 2200 MHz | Return Loss: ≤-24 dB | VSWR: ≤ 1.140:1 | 
| 2200 to 2500 MHz | Return Loss: ≤-24 dB | VSWR: ≤ 1.140:1 | 
| 2500 to 3000 MHz | Return Loss: ≤-24 dB | VSWR: ≤ 1.140:1 | 
| Electrical Specifications | |
| Impedance | 50 ± 1 Ω | 
| Relative Velocity of Propogation | 88% | 
| Capacitance (1kHz) | 76 pF/m | 
| Inductance | 0.190 µH/m | 
| Maximum Operating Frequency | 8.8 GHz | 
| Cut-off Frequency | 10.0 GHz | 
| Peak Power Rating | 40 kW | 
| Insulation Resistance | ≥ 10 GΩ x km | 
| DC Breakdown Voltage | 6000 V | 
| Jacket Spark Test Voltage | 8000 Vrms | 
| Inner Conductor DC-resistance | ≤ 1.5 Ω /km | 
| Outer Conductor DC-resistance | ≤ 2.3 Ω /km | 
| Attenuation | ||
| Frequenxy (MHz) | Attenuation (dB/100m) | Average Power (kW) | 
| 1 | 0.20 | 35.89 | 
| 100 | 2.15 | 3.94 | 
| 200 | 3.08 | 2.75 | 
| 300 | 3.81 | 1.99 | 
| 400 | 4.46 | 1.80 | 
| 450 | 4.70 | 1.80 | 
| 800 | 6.35 | 1.33 | 
| 900 | 6.75 | 1.25 | 
| 1000 | 7.20 | 1.18 | 
| 1800 | 9.90 | 0.86 | 
| 2000 | 10.50 | 0.81 | 
| 2200 | 11.10 | 0.77 | 
| 2500 | 11.95 | 0.73 | 
| 2700 | 12.47 | 0.69 | 
| 3000 | 13.20 | 0.65 | 
| Standard Conditions | |
| Attenuation, Ambient Temperature | 20̊ C | 
| Average Power, Ambient Temperature | 40̊ C | 
| Average Power, Inner Conductor Temperature | 100̊ C | 
| Ordering Information | ||
| Part Number | Description | UOM | 
| AAT-12-FC | 1/2” 50 ohm Coaxial Cable | Per Ft. | 
Disclaimer: Specifications are subject to change without notice. Information may be changed or updated without notice. American Amplifier TechnologiesTM may also make improvements and/or changes in the products and/or pricing described at any time without notice.
 
            