Features:
- Ultra low attenuation
- Copper Shield
- Low VSWR
- Wide Frequency Range
- Excellent Power Rating
- UV Resistant
- Gas block or Gas Pass
|
Materials and Dimensions |
|
|
Inner conductor-helicat corrugated copper |
17.7 mm / .697 in |
|
Dialectric-foam PE |
42.6 mm / 1.677 in |
|
Outer conductor- corrugated copper tube |
46.4 mm / 1.827 in |
|
Diameter over outer jacket- polythylene black |
50.0 mm / 1.969 in |
|
Mechanical Specifications |
|
|
Cable Weight |
1.06 kg/m, 0.712 lb/ft |
|
Tensile Strength |
2400 N | 539 lbs. |
|
Min. Bending Radius (single) |
300 mm | 11.8 in |
|
Min. Bending Radius (repeated) |
500 mm | 19.6 in |
|
Number of bends, minimum (typical) |
15 (50) |
|
Recommended Hanger Spacing |
1.2 m | 4 ft. |
|
Environmental Specifications |
|
|
Installation Temperature |
-25°C to +60°C |
|
Operating Temperature |
-40°C to +85°C |
|
Storage Temperature |
-70°C to +85°C |
|
2002/95/EC (RoHS) |
compliant |
|
Return Loss |
|
|
1 to 1000 MHz |
Return Loss: ≤-26 dB | VSWR: ≤1.105:1 |
|
1000 to 2500 MHz |
Return Loss: ≤-24 dB | VSWR: ≤1.140:1 |
|
Electrical Specifications |
|
|
Impedance |
50 ± 1 Ω |
|
Relative Velocity of Propogation |
90% |
|
Capacitance (1kHz) |
75 ± 1.5 pF/m |
|
Maximum Operating Frequency |
2.5 GHz |
|
Cut-off Frequency |
2.68 GHz |
|
Peak Power Rating |
306 kW |
|
Insulation Resistance |
≥ 10 GΩ x km |
|
Operating Voltage |
5400 Vrms |
|
DC Breakdown Voltage |
15000 V |
|
Jacket Spark Test Voltage |
11000 Vrms |
|
Inner Conductor DC-resistance |
≤ 1.42 Ω /km |
|
Outer Conductor DC-resistance |
≤ 0.65 Ω /km |
|
Attenuation |
||
|
Frequenxy (MHz) |
Attenuation (dB/100m) |
Average Power (kW) |
|
1 |
0.06 |
182.21 |
|
80 |
0.59 |
16.21 |
| 100 | 0.63 | 17.49 |
|
150 |
0.83 |
11.61 |
|
450 |
1.47 |
6.37 |
|
824 |
2.06 |
4.51 |
|
900 |
2.16 |
4.29 |
|
1000 |
2.28 |
4.03 |
|
1800 |
3.17 |
2.85 |
|
2000 |
3.37 |
2.67 |
|
2200 |
3.58 |
2.52 |
|
2500 |
3.83 |
2.32 |
|
Standard Conditions |
|
|
Attenuation, Ambient Temperature |
20̊ C |
|
Average Power, Ambient Temperature |
40̊ C |
|
Average Power, Inner Conductor Temperature |
100̊ C |
|
Ordering Information |
||
|
Part Number |
Description |
UOM |
|
AAT-158-FC |
1 5/8” 50 ohm Coaxial Cable |
Per Ft. |
Disclaimer: Specifications are subject to change without notice. Information may be changed or updated without notice. American Amplifier TechnologiesTM may also make improvements and/or changes in the products and/or pricing described at any time without notice.