Features:
- Ultra low attenuation
- Copper Shield
- Low VSWR
- Wide Frequency Range
- Excellent Power Rating
- UV Resistant
|
Materials and Dimensions |
|
|
Inner conductor-helicat corrugated copper |
4.8 mm / 0.189 in |
|
Dialectric-foam PE |
12.1 mm / 0.476 in |
|
Outer conductor- corrugated copper tube |
13.8 mm / 0.543 in |
|
Diameter over outer jacket- polythylene black |
15.9 mm / 0.626 in |
|
Mechanical Specifications |
|
|
Cable Weight |
0.17 kg/m | 0.114 lbs/ft |
|
Tensile Strength |
1150 N | 258 lbs |
|
Min. Bending Radius (single) |
71 mm | 2.79 inches |
|
Min. Bending Radius (repeated) |
125 mm | 4.96 inches |
|
Number of bends, minimum (typical) |
15 (50) |
|
Recommended Hanger Spacing |
0.8 m | 2.62 ft |
|
Environmental Specifications |
|
|
Installation Temperature |
-25°C to +60°C |
|
Operating Temperature |
-40°C to +85°C |
|
Storage Temperature |
-70°C to +85°C |
|
2002/95/EC (RoHS) |
compliant |
|
Return Loss |
|
|
1 to 1000 MHz |
Return Loss: ≤-26 dB | VSWR: ≤ 1.105:1 |
|
1000 to 1900 MHz |
Return Loss: ≤-24 dB | VSWR: ≤ 1.140:1 |
|
1900 to 2200 MHz |
Return Loss: ≤-24 dB | VSWR: ≤ 1.140:1 |
|
2200 to 2500 MHz |
Return Loss: ≤-24 dB | VSWR: ≤ 1.140:1 |
|
2500 to 3000 MHz |
Return Loss: ≤-24 dB | VSWR: ≤ 1.140:1 |
|
Electrical Specifications |
|
|
Impedance |
50 ± 1 Ω |
|
Relative Velocity of Propogation |
88% |
|
Capacitance (1kHz) |
76 pF/m |
|
Inductance |
0.190 µH/m |
|
Maximum Operating Frequency |
8.8 GHz |
|
Cut-off Frequency |
10.0 GHz |
|
Peak Power Rating |
40 kW |
|
Insulation Resistance |
≥ 10 GΩ x km |
|
DC Breakdown Voltage |
6000 V |
|
Jacket Spark Test Voltage |
8000 Vrms |
|
Inner Conductor DC-resistance |
≤ 1.5 Ω /km |
|
Outer Conductor DC-resistance |
≤ 2.3 Ω /km |
|
Attenuation |
||
|
Frequenxy (MHz) |
Attenuation (dB/100m) |
Average Power (kW) |
| 1 | 0.20 | 35.89 |
|
100 |
2.15 |
3.94 |
|
200 |
3.08 |
2.75 |
|
300 |
3.81 |
1.99 |
|
400 |
4.46 |
1.80 |
|
450 |
4.70 |
1.80 |
|
800 |
6.35 |
1.33 |
|
900 |
6.75 |
1.25 |
|
1000 |
7.20 |
1.18 |
|
1800 |
9.90 |
0.86 |
|
2000 |
10.50 |
0.81 |
|
2200 |
11.10 |
0.77 |
|
2500 |
11.95 |
0.73 |
|
2700 |
12.47 |
0.69 |
|
3000 |
13.20 |
0.65 |
|
Standard Conditions |
|
|
Attenuation, Ambient Temperature |
20̊ C |
|
Average Power, Ambient Temperature |
40̊ C |
|
Average Power, Inner Conductor Temperature |
100̊ C |
|
Ordering Information |
||
|
Part Number |
Description |
UOM |
|
AAT-12-FC |
1/2” 50 ohm Coaxial Cable |
Per Ft. |
Disclaimer: Specifications are subject to change without notice. Information may be changed or updated without notice. American Amplifier TechnologiesTM may also make improvements and/or changes in the products and/or pricing described at any time without notice.