{"product_id":"p91-series-online-ups-copy","title":"P91 Series Online UPS Scalable Runtime Rack\/Tower UPS (1000–3000VA, 120V)","description":"\u003cp\u003e1000–3000 VA | 120V | Online Double-Conversion UPS\u003c\/p\u003e\n\u003cp\u003eRuntime-flexible online UPS engineered for distributed IT, AV, retail, and multi-site infrastructure requiring continuous power conditioning and scalable runtime.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"UTF-8\"\u003e\u003cspan\u003eThe P91 is a 120 V online double-conversion UPS built around a flexible VRLA battery architecture: internal batteries provide standard ride-through, while external battery packs extend runtime to match the application. Online topology continuously conditions incoming power with zero transfer time, and near-unity power factor (2U units) delivers maximum usable watts — all in a compact 2U rack\/tower form factor (plus a 1U model). It is \u003c\/span\u003e\u003cstrong\u003eTAA compliant\u003c\/strong\u003e\u003cspan\u003e(made in Taiwan; UL \/ cUL listed) for federal, education, and public-sector procurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0070\/5091\/9983\/files\/P91-1-3kVA-Flyer.pdf?v=1782318548\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003eClick for Produtct Flyer\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"font-size: large;\" size=\"4\"\u003eProduct Snapshot\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul class=\"check\"\u003e\n\u003cli\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv class=\"xpc-p91vp-feature-title\"\u003eOnline double-conversion\u003c\/div\u003e\n\u003cp class=\"xpc-p91vp-feature-desc\"\u003eZero transfer time and continuous conditioning – pure sine output at ≤2% THD (linear) \/ ≤4% THD (non-linear) on 2U units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv class=\"xpc-p91vp-feature-title\"\u003eScalable external batteries\u003c\/div\u003e\n\u003cp class=\"xpc-p91vp-feature-desc\"\u003eAdd up to seven matching packs (BP36 \/ BP48 \/ BP72) to take a rack from a few minutes of ride-through to over two hours — enough to outlast most outages or bridge to a generator — then recharge to 95% in under 3 hours.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv class=\"xpc-p91vp-feature-title\"\u003eNear-unity power factor\u003c\/div\u003e\n\u003cp class=\"xpc-p91vp-feature-desc\"\u003e2U units deliver near-unity output power factor — up to 1450 W from a 1500 VA frame, more usable watts than the 1350 W typical of competing online units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv class=\"xpc-p91vp-feature-title\"\u003ePowerful 8 A charger\u003c\/div\u003e\n\u003cp class=\"xpc-p91vp-feature-desc\"\u003eAn adjustable charger (up to 8 A) quickly recharges internal batteries and up to seven external packs; recharge to 95% in under 3 hours.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cmeta charset=\"UTF-8\"\u003e\n\u003cdiv class=\"xpc-p91vp-feature-title\"\u003eMaintenance bypass + auto-restart\u003c\/div\u003e\n\u003cp class=\"xpc-p91vp-feature-desc\"\u003eAn optional XBDM bypass lets you service or swap the UPS without dropping the rack; after a full discharge, auto-restart brings the load back the moment utility returns — no truck roll to power-cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv class=\"xpc-p91vp-feature-title\"\u003eEfficient + monitored\u003c\/div\u003e\n\u003cp class=\"xpc-p91vp-feature-desc\"\u003eUp to 98% ECO-mode efficiency, with optional Web\/SNMP, Modbus, and relay\/dry-contact monitoring cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\n\u003cdiv title=\"Page 1\" class=\"page\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cb\u003e\u003cspan style=\"font-size: large;\" size=\"4\"\u003eFEATURES\u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe P91 operates as the standard online UPS platform within distributed power architecture, providing conditioned power and scalable runtime at the rack or edge level. It is typically deployed in network closets, IDF\/MDF environments, and multi-site infrastructure where runtime requirements vary but platform standardization is required.\u003c\/span\u003e\u003cspan\u003eMODEL SELECTION GUIDE\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column\"\u003e\n\u003cdiv title=\"Page 2\" class=\"page\"\u003e\n\u003cdiv class=\"xpc-p91vp-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMODEL\u003c\/th\u003e\n\u003cth\u003eCAPACITY\u003c\/th\u003e\n\u003cth\u003eFORM FACTOR\u003c\/th\u003e\n\u003cth\u003eRECEPTACLES\u003c\/th\u003e\n\u003cth\u003eDIMENSIONS (W×D×H)\u003c\/th\u003e\n\u003cth\u003eWEIGHT\u003c\/th\u003e\n\u003cth\u003eINTERNAL BATTERY\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eP91c-1000\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 800 W\u003c\/td\u003e\n\u003ctd\u003e1U\u003c\/td\u003e\n\u003ctd\u003e(3) NEMA 5-15R\u003c\/td\u003e\n\u003ctd\u003e17.2 × 17.8 × 1.7 in\u003c\/td\u003e\n\u003ctd\u003e28 lb\u003c\/td\u003e\n\u003ctd\u003e(4) 6V 290W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP91-1000\u003c\/td\u003e\n\u003ctd\u003e1000 VA \/ 1000 W\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003ctd\u003e(8) NEMA 5-15R\u003c\/td\u003e\n\u003ctd\u003e17.2 × 15.1 × 3.5 in\u003c\/td\u003e\n\u003ctd\u003e25.5 lb\u003c\/td\u003e\n\u003ctd\u003e(2) 12V 9Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP91-1500\u003c\/td\u003e\n\u003ctd\u003e1500 VA \/ 1450 W\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003ctd\u003e(8) NEMA 5-15R\u003c\/td\u003e\n\u003ctd\u003e17.2 × 15.1 × 3.5 in\u003c\/td\u003e\n\u003ctd\u003e34.2 lb\u003c\/td\u003e\n\u003ctd\u003e(3) 12V 9Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP91-2000\u003c\/td\u003e\n\u003ctd\u003e2000 VA \/ 1930 W\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003ctd\u003e(8) NEMA 5-15\/20R\u003c\/td\u003e\n\u003ctd\u003e17.2 × 19.0 × 3.5 in\u003c\/td\u003e\n\u003ctd\u003e43 lb\u003c\/td\u003e\n\u003ctd\u003e(4) 12V 9Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP91-3000\u003c\/td\u003e\n\u003ctd\u003e3000 VA \/ 2880 W\u003c\/td\u003e\n\u003ctd\u003e2U\u003c\/td\u003e\n\u003ctd\u003e(1) L5-30R + (6) 5-15\/20R\u003c\/td\u003e\n\u003ctd\u003e17.2 × 23.8 × 3.5 in\u003c\/td\u003e\n\u003ctd\u003e60.6 lb\u003c\/td\u003e\n\u003ctd\u003e(6) 12V 9Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"xpc-p91vp-p\"\u003e2U units offer near-unity power factor and selectable output (100\/110\/115\/120\/127 VAC). Rack depth is measured front bracket to unit panel; add 1 in for the front bezel. The P91c-1000 is a 1U model with internal batteries only.\u003c\/p\u003e\n\u003cp class=\"xpc-p91vp-p\"\u003e \u003c\/p\u003e\n\u003ch2 class=\"xpc-p91vp-h2\"\u003eP91 specifications\u003c\/h2\u003e\n\u003cdiv class=\"xpc-p91vp-wrap\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSPECIFICATION\u003c\/th\u003e\n\u003cth\u003eDETAIL\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTopology\u003c\/td\u003e\n\u003ctd\u003eOnline double-conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e1000 \/ 1000 \/ 1500 \/ 2000 \/ 3000 VA (800–2880 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput power factor\u003c\/td\u003e\n\u003ctd\u003eNear-unity (up to 1.0 on 2U units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e55–150 VAC (load dependent), 50\/60 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC nominal; 100 \/ 110 \/ 115 \/ 127 VAC selectable (2U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput waveform\u003c\/td\u003e\n\u003ctd\u003ePure sine wave; 2U ≤2% \/ ≤4% THD, 1U ≤3% \/ ≤5% THD (linear \/ non-linear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz (±0.1 Hz on 2U, ±0.3 Hz on 1U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 98% (ECO mode) \/ 94% (online mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eSealed, maintenance-free VRLA (lead-acid); internal + external pack expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal battery packs\u003c\/td\u003e\n\u003ctd\u003eBP36 \/ BP36E \/ BP48 \/ BP72; up to 7 packs (1500 \/ 2000 \/ 3000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecharge\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;3 h to 95% (2U, 2 A); \u0026lt;9 h to 90% (1U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharger current\u003c\/td\u003e\n\u003ctd\u003eUp to 8 A adjustable (2U); 1 A (1U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm factor\u003c\/td\u003e\n\u003ctd\u003e2U rack \/ tower (P91c-1000 is 1U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e32–104°F (0–40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 6,500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eRS-232 (2U), USB, EPO; intelligent slot (Web\/SNMP, relay\/dry contact, Modbus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eUL, cUL, RoHS, FCC Class A\/B; TAA compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad protection policy\u003c\/td\u003e\n\u003ctd\u003e$50,000 connected-equipment protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e3-year electronics \u0026amp; battery (USA \u0026amp; Canada); optional 5-year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003eViewPower software, front brackets, tower pedestals, user manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptions\u003c\/td\u003e\n\u003ctd\u003eBypass distribution (XBDM), power distribution (XPDU), matching battery packs, 4-post rail kit, 2-post shelf kit, wall-mount bracket (2U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"xpc-p91vp-p\"\u003eSpecifications from the P91 1-3kVA datasheet (Rev 4\/6\/20). Capacities are based on the highest selectable voltage; some models derate at lower voltages. For 230 V online models, reference the P91g.\u003cmeta charset=\"UTF-8\"\u003e\u003c\/p\u003e\n\u003ctable width=\"794\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"119\"\u003e\u003c\/td\u003e\n\u003ctd width=\"117\"\u003eMODEL NUMBER\u003c\/td\u003e\n\u003ctd width=\"121\"\u003eP91c-1000\u003c\/td\u003e\n\u003ctd width=\"117\"\u003eP91-1000\u003c\/td\u003e\n\u003ctd width=\"104\"\u003eP91-1500\u003c\/td\u003e\n\u003ctd width=\"102\"\u003eP91-2000\u003c\/td\u003e\n\u003ctd width=\"114\"\u003eP91-3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPACITY\u003c\/td\u003e\n\u003ctd\u003ePower rating\u003c\/td\u003e\n\u003ctd\u003e1000VA (800W)\u003c\/td\u003e\n\u003ctd\u003e1000VA (1000W)\u003c\/td\u003e\n\u003ctd\u003e1500VA (1450W)\u003c\/td\u003e\n\u003ctd\u003e2000VA (1930W)\u003c\/td\u003e\n\u003ctd\u003e3000VA (2880W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINPUT\u003c\/td\u003e\n\u003ctd\u003eVoltage\/frequency\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e    55–150VAC* \/  50\/60Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOUTPUT\u003c\/td\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e120VAC\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e120VAC nominal (100\/110\/115\/127 selectable)***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eWaveform\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003ePure sine wave, 1U: \u0026lt;=3% THD (linear load), \u0026lt;=5% THD (non-linear load); 2U: \u0026lt;=2% THD (linear load), \u0026lt;=4 THD (non-linear load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz ± 0.3Hz\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e50\/60Hz ± 0.1Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eUp to 98% ECO mode or 94% online mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOverload capacity\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1U online mode: \u0026gt; 105% \u0026amp; ≤ 130% for 2 min; \u0026gt; 130% \u0026amp; ≤200% for 10 sec; \u0026gt;200% for 250 ms \/ 2U online mode: \u0026gt; 110% \u0026amp; ≤ 130% for 5 min; \u0026gt; 130% \u0026amp; ≤140% for 30 sec; \u0026gt;140% for 1.5 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBATTERY\u003c\/td\u003e\n\u003ctd\u003eBattery chemistry\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eSealed, maintenance-free lead acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBattery  size\u003c\/td\u003e\n\u003ctd\u003e(4) 6V 290W\u003c\/td\u003e\n\u003ctd\u003e(2) 12V 9AH\u003c\/td\u003e\n\u003ctd\u003e(3) 12V 9AH\u003c\/td\u003e\n\u003ctd\u003e(4) 12V 9AH\u003c\/td\u003e\n\u003ctd\u003e(6) 12V 9AH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eTypical recharge \/ charger\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 9 hours to 90%\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u0026lt; 3 hours to 95% with 2A charger current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCharging current\u003c\/td\u003e\n\u003ctd\u003e1A\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2A default,  max 8A adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePHYSICAL\u003c\/td\u003e\n\u003ctd\u003eDimensions (W x D x H)**\u003c\/td\u003e\n\u003ctd\u003e17.2 x 17.8 x 1.7 in\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e17.2 x 15.1 x 3.5 in\u003c\/td\u003e\n\u003ctd\u003e17.2 x 19 x 3.5 in\u003c\/td\u003e\n\u003ctd\u003e17.2 x 23.8 x 3.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e28 lbs\u003c\/td\u003e\n\u003ctd\u003e25.5 lbs\u003c\/td\u003e\n\u003ctd\u003e34.2 lbs\u003c\/td\u003e\n\u003ctd\u003e43 lbs\u003c\/td\u003e\n\u003ctd\u003e60.6 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLine cord\u003c\/td\u003e\n\u003ctd\u003eC14 inlet, 5ft 5-15P to C13 line cord\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6 ft, 5–15P\u003c\/td\u003e\n\u003ctd\u003e6 ft, 5–20P\u003c\/td\u003e\n\u003ctd\u003e6 ft, L5–30P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eReceptacles\u003c\/td\u003e\n\u003ctd\u003e(3) NEMA 5–15R\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e(8) NEMA 5-15R\u003c\/td\u003e\n\u003ctd\u003e(8) NEMA 5–15\/20R\u003c\/td\u003e\n\u003ctd\u003eL5–30R + (6) 5–15\/20R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eENVIRONMENT\u003c\/td\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e32–104°F (0–40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e11,500 ft above sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAPPROVALS\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eUL, cUL, RoHS, FCC Class B (1000 (2U), 1500VA), FCC Class A (1000 (1U), 2000, 3000VA), TAA compliant (UPS only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWARRANTY\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e3 years electronics, 3 years battery warranty (USA and Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOMMUNICATIONS INTERFACE\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eRS-232(2U), USB, EPO, intelligent slot for optional cards (Web\/SNMP, Relay\/dry contact, Modbus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eINCLUDED IN BOX\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eViewPower software,front brackets, tower pedestals, user manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAVAILABLE OPTIONS\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eBypass distribution (XBDM), power distribution (XPDU), 4-post rail kit, 2-post shelf kit, wall mount bracket (2U units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"AmericanAmpTech","offers":[{"title":"P91c-1000","offer_id":45594481524915,"sku":null,"price":1170.0,"currency_code":"USD","in_stock":true},{"title":"P91-1000","offer_id":45594481557683,"sku":null,"price":1220.0,"currency_code":"USD","in_stock":true},{"title":"P91-1500","offer_id":45594481590451,"sku":null,"price":1595.0,"currency_code":"USD","in_stock":true},{"title":"P91-2000","offer_id":45594491814067,"sku":null,"price":2080.0,"currency_code":"USD","in_stock":true},{"title":"P91-3000","offer_id":45594491846835,"sku":null,"price":2770.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0070\/5091\/9983\/files\/P91.jpg?v=1782317928","url":"https:\/\/www.americanamptech.com\/products\/p91-series-online-ups-copy","provider":"American Amplifier Technologies","version":"1.0","type":"link"}